This unit answers the need for a dimmer which will automatically fade up (or down), hold at a preset level and then fade back to the start. The controller card is available separately from the dimmer and is user and/or factory programmable for all of the parameters. Programmable and operational options include: Start Level Rise Time Hold Level Hold Time Fall Time Three trigger modes Flicker On/Off/Depth/Rate Flasher On/Off/Rate Automatic Recycle after completion Pause Time between Recycle Force ON Force OFF Abort Cycle Closure inputs for all functions |
|
AUTOMATIC FADING CONTROLLER/DIMMER Model L129 |
|
Tremendous additional operational flexibility is available. Features and options include: Programmable Fade Time ranges from 1 - 10,000 seconds (that's almost a 3 hour fade) All digital operation, values stored in EEROM for retention without power - no trimmers or adjustments Start Level may be higher or lower than Hold Level Proper theatrical dimming curve Well filtered output, 2.2" semi epoxy encapsulated choke Dual SCR output stage Work light control (Force On / Force Off) Automatic detection of 50/60Hz Flicker generation during Hold phase with adjustable parameters and random number generator Flasher during Hold phase, Full ON to Full Off, adjustable rate Programmed settings are secure because the programming unit is separate; nobody can mess up your settings Only one program data loader needed for many units saves cost |


|
start level |
|
hold level |
|
start level |
|
full level |
|
off level |
|
levels may be inverted from picture |
|
hold time |
|
(recycle time) |

|
After starting (triggering), the output executes the following basic Cycle: Fade from a Start Level to a Hold Level, Hold at that level, and then fade back to the Start Level. |
|
The PIC/AXE program data loader is an optional hand held accessory with switches and an LCD Display and is used to program the various time and level settings. Once programmed with the PIC/AXE (or at the factory) the L129 is a stand-alone controller. The PIC/AXE can also function as a remote control in Run mode. The control section may be supplied separately or with an integral dimmer. If control section is ordered separately, its output can be configured as 0 to 10VDC or 0 to 5VDC Control (or consult regarding DMX-512) to control an external dimmer. |